OTL Report No. 116-F-39C-5
Portland
MODELS
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases unless a certified kit is used.
INSTALLATION INSTRUCTIONS
ELDV Direct-Vent
Gas Fireplaces
ELDV-35NM
ELDV-40NM
ELDV-45NM
ELDV-35PM
ELDV-40PM
ELDV-45PM
MILLIVOLT:
ELDV-35NE
ELDV-40NE
ELDV-45NE
ELECTRONIC:
P/N 850036M Rev. I 09/2012
This manual is one of a set of two supporting this product.
Refer to P/N 875030M for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 850036CF.
AVERTISSEMENT : Assurez-vous de bien suivre les
instructions données dans cette notice pour réduire au
minimum le risque d’incindie ou d’explosion ou pour
éviter tout dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
-
L’installation et l’entretien doivent être assurés par un
installateur ou un service d’entretien qualifié ou par le
fournisseur de gaz.
WARNING: If the information in these instructions
is not followed exactly, a fire or explosion may
result, causing property damage, personal injury,
or death.
-
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.
department.
- Installation and service must be performed by a
WARNING
/
AVERTISSEMENT
/
AVISO
HOT GLASS WILL CAUSE
BURNS.
DO NOT TOUCH GLASS
UNTIL COOLED.
NEVER ALLOW CHILDREN
TO TOUCH GLASS.
UNE SURFACE VITRÉE CHAUDE
PEUT CAUSER DES BRÛLURES.
LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR : Laissez cette notice avec l'appareil.
CONSOMMATEUR : Conservez cette notice pour
consultation ultérieure.
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - AVERTISSEMENT

OTL Report No. 116-F-39C-5PortlandMODELSThis appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile

Page 2 - AVERTISSEMENT

10NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.FIREPLACE AND FRAMING SPECIFICATIONSVent SizeCo-axial DV Vent Size4-1/2" Inner 7-1/2"

Page 3 - Efficiencies %

11NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.FIREPLACE FRAMING SPECIFICATIONSFigure 14 - Corner Framing with Horizontal TerminationSchedule

Page 4 - HTPTHTPT

12NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Step 3. INSTALL THE VENT SYSTEM General InformationThese instructions should be used as a guidel

Page 5 - VERTICAL VENT

13NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Note: Convert inches into metric equivalent measurement, as follows:Millimeters (mm) = Inches x

Page 6 - Side Elevation View

14NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Push the vent component against the previous section until it fully engages, then twist the comp

Page 7 - Figure 7

15NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.If the vent system extends more than 5 feet (1.5m) above the roof flashing, stabilizers may be ne

Page 8

16NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. u Ceiling Firestop / Spacer (SV4.5VF)v When using Se-cure Flex, use Firestop / Spac-er SF4.5VF

Page 9

17NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Maintain a minimum 1" (25 mm) clearance to combustibles on the vertical sections. Clear-anc

Page 10 - Figure 13

18NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Support BracketsBuildingSupportFramingSV4.5E90ElbowCeilingFireplaceSV4.5L6/12/24/36/48Vent Secti

Page 11

19NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.J. Assemble vent run to exterior wall - If not previously measured, locate the center of the ven

Page 12 - Restrictor

2TABLE OF CONTENTS Packaging ...Page 2Introduction ...Page 2General Informati

Page 13 - Figure 17

20NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.See Table 9 as an aid in venting component selection for a particular range of exterior wall thi

Page 14 - Figure 20

21NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Figure 32 - Top Vent - TWO 90 DEGREE ELBOWSSee Table 9 on Page 20 as an aid in venting component

Page 15 - Figure 24

22NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.VHH1V1Wall Firestop/Spacer(SV4.5HF)CeilingFirestop/Spacer(SV4.5VF)When using Secure FlexTM,use F

Page 16 - WARNING

23NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.D. Install Firestop / Spacers at ceilings and walls - When Secure Flex penetrates a wall or ceil

Page 17

24NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Step 4. FIELD WIRINGB. Electronic Wiring (See Figure 37) – Note: The electronic appliance must

Page 18 - Figure 28

25NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Note: Remote receiver should be located in the wall, or if installed in the control compartmen

Page 19 - **For thicknesses greater

26NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Figure 40Step 6. CONNECTING GAS LINE All codes require a shut-off valve mounted in the supply li

Page 20

27NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Turn on gas supply and test for gas leaks, us-ing a gas leak test solution (also referred to as

Page 21 - (SV4.5VF)

28NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.REFERENCEFirebox Accessories / PartsCat. No. Model No. Description88L53 FGE Bag of Glowing Ember

Page 22 - Section Required

29NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.ELDV3530 LOG PLACEMENT Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front

Page 23 - Figure 35

3 WARNING Improper installation, adjust-ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. Fo

Page 24 - JUNCTION BOX

30NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.ELDV4035 LOG PLACEMENT Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front

Page 25 - BLOWER KIT

31NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. Log Number Description 1 Log, Center 2 Log, Rear 3 Log, Front 4 Log, Left 5 Log,

Page 26 - Flex Line Connector

32NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Step 9. REMOVING AND INSTALLING THE GLASS DOOR Air Shutter Adjustment Guidelines:Amount of Prim

Page 27 - Never use an open flame to

33NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNINGS• Air shutter adjustment should only be performed by a quali-fied professional serv

Page 28

34NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Step 11. HOOD INSTALLATIONThe hood is optional for these products. In "Shadow Box" in

Page 29 - ELDV3530 LOG PLACEMENT

35NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.STEP 12. ATTACHING SAFETY-IN-OPERATION WARNINGSIt is the installers responsibility to ensure th

Page 30 - ELDV4035 LOG PLACEMENT

36NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Cat. No. Model Description77L70 SV4.5L6 6 Inch (152 mm) 77L71 SV4.5L12 12 Inch (305 mm) 77L72 SV

Page 31 - ELDV4540 LOG PLACEMENT

37NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Cat. # Model DescriptionH1969 SF4.5HT-2 Horizontal Square Termina-tion for flex (without flex)77L8

Page 32

38NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Millivolt SIT SystemsPropane Gas to Natural GasConversion KitsModels Catalog No.ELDV-35 H3960ELD

Page 33 - CAUTIONS

39NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Figure 55Millivolt AppliancesStep 5. SIT Systems - Refer to Figure 56 and the instructions pro

Page 34 - Figure 54

4NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.Figure 2 - Dexen Electronic Gas ValvePilot StageTerminalPressure-Tap(Inlet)Pilot GasOutletSupplyG

Page 35

Printed in U.S.A. © 2012 Lennox Hearth ProductsP/N 850036M Rev. I 09/2012 1508ElmHillPike,Suite108•Nashville,TN37210Lennox Hearth Product

Page 36 - INSTALLATION ACCESSORIES

5NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.• A hard wired carbon monoxide detectorwith an alarm and battery back-up must be installed

Page 37

6NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.12 X Roof Pitch is X/12 2 FT MIN. 2 FT MIN. Lowest Discharge Opening H* *H = MINIMUM HEIGHT FROM

Page 38

7NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS Figure 7VVVVVFCFixedClosedWindowOpera

Page 39 - Assembly

8NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.5 (127)8-1/4(209)14(356)12 (305)17 (431)*Shelf Height(see table)Do not insulate thespace between

Page 40

9NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. WARNING Failure to position the parts in accordance with these diagrams or failure to use